Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.8753240

- Product Categories
- Friendly Links
- home > Supply > Wuhan ozone aging test is still measured the best quality, ozone aging test chamber Wuhan lowest price
Wuhan ozone aging test is still measured the best quality, ozone aging test chamber Wuhan lowest price
Information Name: | Wuhan ozone aging test is still measured the best quality, ozone aging test chamber Wuhan lowest price |
Published: | 2012-03-17 |
Validity: | 3000 |
Specifications: | QL-800 |
Quantity: | 10.00 |
Price Description: | |
Detailed Product Description: | Resistance to ozone aging test, ozone aging box A resistance to ozone aging test, ozone aging chamber effect: Resistance to ozone aging test, ozone aging box is suitable for testing vulcanized rubber, organic materials, non-metallic materials resistant to ozone aging and aging cracking tensile test. Second, resistance to ozone aging test, ozone aging box mechanism: Ozone O3 content in the atmosphere of our lives is small but the main factors for surface cracks of various rubber products, resistance to ozone aging test simulation and strengthen the conditions of ozone in the atmosphere to study the role of the law of ozone on rubber rapid identification and evaluation of rubber anti-ozone aging properties antiozonants protection performance, and then take effective anti-aging measures to improve the service life of rubber products. Ozone aging test chamber by a silent and efficient ozone generator ozone gas, and a certain amount of air processed Exchangers mixed into the chamber, UV detector continuously detected the ozone concentration, feedback to the ozone generator control system, control system settings control the occurrence of ozone in the chamber so as to keep the ozone concentration set, and the other by the heated humidification systems to meet all the test conditions. Third, resistance to ozone aging test, ozone aging box model specifications, studio size, Dimensions: 1.QL-100: 450 × 450 × 550; 1150 × 900 × 1650 2.QL-225: 500 × 600 × 750; 1120 × 1100 × 1900 3.QL-500: 800 × 700 × 900; 1350 × 1280 × 2100 4.QL-800: 800 × 1000 × 1000; 1410 × 1430 × 2120 5.QL-010: 1000 × 1000 × 1000; 1650 × 1480 × 2200 Fourth, the resistance to ozone aging test, ozone aging chamber structural features: A resistance to ozone aging test studio three sides of the duct dissection, the distribution of the circulating fan, heating, humidifiers, and other parts, the chamber upper there is a balancing vent needs to be gas in the laboratory continue to discharge in order to maintain the test chamber the balance of the concentration of the gas chamber for a single door, and ozone resistance silicon rubber seal. Resistance to ozone aging test chamber box for the overall structure, measurement and control system located on the right side of the chamber surface, the air handling system in the cabinet after the lower part. Resistance to ozone aging test chamber equipped with multi-layer stainless steel compartment bar shelf. Resistance to ozone aging test chamber located right in front of the intelligent controller for the touch screen. Resistance to ozone aging test with switch control of lighting and observation windows. Resistance to ozone aging test, ozone aging box is a major component: An aging box studio wall is made of SUS304 stainless steel plate forming the wall for easy cleaning. Aging chamber shell is made of high-quality cold rolled sheet metal forming surface electrostatic powder processing. 3 chamber air source electromagnetic oil and gas pump. Chamber stainless steel fin electric heater. 5 surface of the chamber electric light evaporative humidifier. 6. Chamber motors, centrifugal convection fan. 7 mounted in the chamber under the water tank water supply, the water level automatic control. Resistance to ozone aging test to set the gas flow meter, accurate gas flow control at all levels. Resistance to ozone aging chamber is equipped with a silent discharge ozone occurred components. Resistance to ozone aging test. Embedded industrial control one computer (7-inch color touch screen). Resistance to ozone aging test. Equipped with a gas purification device (activated carbon absorption and silica gel drying tower) Resistance to ozone aging chamber insulation layer of rigid polyurethane foam and fine cotton insulation thickness of 100mm. Resistance to ozone aging test chamber prepared to leave the classic chemical test of ozone concentrations interface to facilitate the calibration analysis of the test. 14 resistance to ozone aging test double the speed of light, UV-type ozone detector. Six, resistance to ozone aging test, ozone aging of the box performance benefits: An electromagnetic air pump to provide quality air supply, dry, oil-free to ensure the long-term reliability of the gas system. Air circulation device: built-in circular duct, test airflow evenly from top to bottom parallel to the flow through the specimen surface, in line with GB. . Computer ozone concentration, temperature and humidity control, high integration, reliability, LED display, the display resolution temperature (0.1 ° C), humidity (0.1 ° C), the ozone concentration (10pphm), the PID setpoint control easy to operate. A variety of sample holder device (to meet the static tensile test specimen trajectory to meet the principle of cycloid trajectory and dynamic tensile test, 5 in line with international standards of stainless steel test positions and silent discharge manufacture of ozone in a closed gas circuit, the occurrence and capture of ozone gas is a closed loop, to ensure personal safety. 6. The ozone concentration in automatic control (setpoint control), the PID self-tuning, the volatility is small. Resistance to ozone aging test, ozone aging box Main technical parameters: (1) ozone concentrations: 0 500pphm (2) ozone concentrations: 0 ~ 1000pphm (3) ozone concentrations: 100 ~ 250ppm (optional) Ozone concentration accuracy: ± 10% Temperature uniformity: ± 2 ℃ Laboratory temperature: RT to +10 ~ 80 ℃, -10 ~ 80 ° C (optional) Relative Humidity: 60 ~ 95% RH Sample holder pulled frequency: 0.5Hz (optional) Sample holder rotation speed: 2R/min (optional) 10 test gas flow rate: 20 ~ 70L/min Airflow speed: 12 ~ 16mm / s, 8, resistance to ozone aging test, ozone aging box security measures: A power overload, short circuit protection. Control back to the passing load, ground fault protection, short circuit protection. (3) over-temperature protection, motor overload protection. 4 alarm hearing the snooze alert. |
Admin>>>
You are the 17664 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan is still testing inspection equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 17664 visitor
Copyright © GuangDong ICP No. 10089450, Wuhan is still testing inspection equipment Co., Ltd. All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility